Singapore medical journal ; : 373-378, 2023.
Article in English | WPRIM | ID: wpr-984213

ABSTRACT

INTRODUCTION@#Despite the challenges related to His bundle pacing (HBP), recent data suggest an improved success rate with experience. As a non-university, non-electrophysiology specialised centre in Singapore, we report our experiences in HBP using pacing system analyser alone.@*METHODS@#Data of 28 consecutive patients who underwent HBP from August 2018 to February 2019 was retrospectively obtained. The clinical and technical outcomes of these patients were compared between two timeframes of three months each. Patients were followed up for 12 months.@*RESULTS@#Immediate technical success was achieved in 21 (75.0%) patients (mean age 73.3 ± 10.7 years, 47.6% female). The mean left ventricular ejection fraction was 53.9% ± 12.1%. The indications for HBP were atrioventricular block (n = 13, 61.9%), sinus node dysfunction (n = 7, 33.3%) and upgrade from implantable cardioverter-defibrillator to His-cardiac resynchronisation therapy (n = 1, 4.8%). No significant difference was observed in baseline characteristics between Timeframe 1 and Timeframe 2. Improvements pertaining to mean fluoroscopy time were achieved between the two timeframes. There was one HBP-related complication of lead displacement during Timeframe 1. All patients with successful HBP achieved non-selective His bundle (NSHB) capture, whereas only eight patients had selective His bundle (SHB) capture. NSHB and SHB capture thresholds remained stable at the 12-month follow-up.@*CONCLUSION@#Permanent HBP is feasible and safe, even without the use of an electrophysiology recording system. This was successfully achieved in 75% of patients, with no adverse clinical outcomes during the follow-up period.


Subject(s)
Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Bundle of His , Follow-Up Studies , Stroke Volume , Retrospective Studies , Treatment Outcome , Cardiac Pacing, Artificial/adverse effects , Electrocardiography , Ventricular Function, Left/physiology
3.
Arq. bras. cardiol ; 118(2): 505-516, 2022. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1364318

ABSTRACT

Resumo Fundamento A estimulação ventricular direita convencional aumenta o risco de fibrilação atrial e insuficiência cardíaca em portadores de marca-passo. A estimulação do ramo esquerdo (RE) do sistema His-Purkinje pode evitar os desfechos indesejados da estimulação ventricular direita. Objetivo Analisar retrospectivamente os desfechos intraoperatórios, eletrocardiográficos e os dados clínicos do seguimento inicial de pacientes submetidos à estimulação do RE. Métodos Foram avaliados os parâmetros eletrônicos do implante e eventuais complicações precoces de 52 pacientes consecutivos submetidos à estimulação do sistema de condução. O nível de significância alfa adotado foi igual a 0,05. Resultados 52 pacientes foram submetidos a estimulação do RE do sistema His-Purkinje, obtendo sucesso em 50 procedimentos. 69,2% dos pacientes eram do sexo masculino e a mediana e intervalo interquatil da idade no momento do implante foi de 73,5 (65,0-80,0) anos. A duração do QRS pré-implante foi de 146 (104-175) ms e de 120 (112-130) ms após o procedimento. O tempo de ativação do ventrículo esquerdo foi de 78 (70-84) ms. A amplitude da onda R foi de 12,00 (7,95-15,30) mV, com limiar de estimulação de 0,5 (0,4-0,7) V × 0,4 ms e impedância de 676 (534-780) ohms. O tempo de procedimento foi de 116 (90-130) min e o tempo de fluoroscopia foi de 14,2 (10,0-21,6) min. Conclusão A estimulação cardíaca do sistema de condução His-Purkinje por meio da estimulação do ramo esquerdo é uma técnica segura e factível. Nesta casuística, apresentou alta taxa de sucesso, foi realizada com tempo de procedimento e fluoroscopia baixos e obteve medidas eletrônicas adequadas.


Abstract Background Conventional right ventricular pacing increases the risk of atrial fibrillation and heart failure in pacemaker patients. Stimulation of the left bundle branch (LBB) of the His-Purkinje system can prevent the unwanted outcomes of right ventricular pacing. Objective To retrospectively analyze the intraoperative outcomes, electrocardiographic and clinical data from the initial follow-up of patients submitted to stimulation of the LBB. Methods The electronic parameters of the implant and of possible early complications of 52 consecutive patients submitted to stimulation of the conduction system were evaluated. The adopted significance level was 0.05. Results Fifty-two patients underwent left bundle branch stimulation, with 50 successful procedures; 69.2% of the patients were male, and the median and interquartile range of age at the time of implantation was 73.5 (65.0-80.0) years. The pre-implant QRS duration was 146 (104-175) ms and 120 (112-130) ms after the procedure. The left ventricle activation time was 78 (70-84) ms. The R-wave amplitude was 12.00 (7.95-15.30) mV, with a stimulation threshold of 0.5 (0.4-0.7) V x 0.4 ms and impedance of 676 (534-780) ohms. The procedure duration was 116 (90-130) min, and the fluoroscopy time was 14.2 (10.0-21.6) min. Conclusion Cardiac stimulation of the His-Purkinje conduction system through the stimulation of the left bundle branch is a safe and feasible technique. In this study, it showed a high success rate, with low procedure and fluoroscopy periods, achieving adequate electronic measurements.


Subject(s)
Humans , Male , Bundle of His , Cardiac Pacing, Artificial/methods , Retrospective Studies , Treatment Outcome , Electrocardiography/methods , Heart Conduction System
4.
Arq. bras. cardiol ; 118(2): 488-502, 2022. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1364323

ABSTRACT

Resumo Fundamento A estimulação cardíaca artificial (ECA) por captura direta ou indireta do feixe de His resulta em contração ventricular sincrônica (ECA fisiológica). Objetivos Comparar sincronia cardíaca, características técnicas e resultados de parâmetros eletrônicos entre duas técnicas de ECA indireta do feixe de His: a não seletiva e a parahissiana. Métodos Intervenção experimental (novembro de 2019 a abril de 2020) com implante de marca-passo definitivo (MPd) DDD em pacientes com fração de ejeção ventricular esquerda > 35%. Foram comparadas a sincronia cardíaca resultante mediante algoritmo de análise eletrocardiográfica da variância espacial do QRS e as características técnicas associadas a cada método entre ECA hissiana não seletiva (DDD-His) e parahissiana (DDD-Var). Resultados De 51 pacientes (28 homens), 34 (66,7%) foram alocados no grupo DDD-Var e 17 (33,3%), no grupo DDD-His, com idade média de 74 e 79 anos, respectivamente. No grupo DDD-Var, a análise da variância espacial do QRS (índice de sincronia ventricular) mostrou melhora após o implante de MPd (p < 0,001). Ao ECG pós-implante, 91,2% dos pacientes do grupo DDD-Var mostraram padrão fisiológico de ECA, comprovando ativação similar à do DDD-His (88,2%; p = 0,999). O eixo do QRS estimulado também foi similar (fisiológico) para ambos os grupos. A mediana do tempo de fluoroscopia do implante foi de 7 minutos no grupo DDD-Var e de 21 minutos no DDD-His (p < 0,001), favorecendo a técnica parahissiana. A duração média do QRS aumentou nos pacientes do DDD-Var (114,7 ms pré-MPd e 128,2 ms pós-implante, p = 0,044). A detecção da onda R foi de 11,2 mV no grupo DDD-Var e de 6,0 mV no DDD-His (p = 0,001). Conclusão A ECA parahissiana comprova recrutamento indireto do feixe de His, mostrando-se uma estratégia eficaz e comparável à ECA fisiológica ao resultar em contração ventricular sincrônica similar à obtida por captura hissiana não seletiva.


Abstract Background Artificial cardiac pacing by direct or indirect His bundle capture results in synchronous ventricular contraction (physiological pacing). Objectives To compare cardiac synchronization, technical characteristics, and electronic parameters between two techniques of indirect His-bundle pacing: non-selective (NS-HBP) vs para-Hisian pacing (PHP). Methods The experimental intervention (between November 2019 and April 2020) consisted of implanting a DDD pacemaker in patients who had left ventricular ejection fraction (LVEF) > 35%. The resulting cardiac synchronization was compared using an electrocardiographic algorithm that analyzed QRS variation and the technical characteristics of non-selective Hisian pacing (DDD-His) and para-Hisian pacing (DDD-Var). Results Of 51 total patients (men: 28), 66.7% (34) were allocated to the DDD-Var group and 33.3% (17) to the DDD-His group. The mean ages in each group were 74 and 79 years, respectively. In the DDD-Var group, QRS variation (ventricular synchrony) improved after implantation (p < 0.001). In post-implantation ECG, 91.2% of the DDD-Var group presented a physiological pacing pattern, which was similar to the DDD-His group (88.2%; p = 0.999). The paced QRS axis was also similar (physiological) for both groups. Intraoperative fluoroscopy time (XRay) during implantation was lower for the para-Hisian technique (median 7 min in the DDD-Var group vs 21 min in the DDD-His group, p < 0.001). The mean QRS duration increased in the DDD-Var group (114.7 ms pre-implantation vs 128.2 ms post-implantation, p = 0.044). The mean post-implantation R-wave amplitude was 11.2 mV in the DDD-Var group vs 6.0 mV in the DDD-His group, p = 0.001. Conclusion Para-Hisian pacing appears to indirectly recruit the His bundle, which would make this an effective and comparable strategy for physiological pacing, resulting in synchronous ventricular contraction similar to that of non-selective Hisian pacing.


Subject(s)
Humans , Male , Aged , Bundle of His , Ventricular Function, Left/physiology , Stroke Volume , Cardiac Pacing, Artificial/methods , Treatment Outcome , Electrocardiography/methods
6.
Chinese Journal of Cardiology ; (12): 142-149, 2022.
Article in Chinese | WPRIM | ID: wpr-935118

ABSTRACT

Objective: To investigate the efficacy and safety of left bundle branch pacing(LBBP) in patients after transcatheter aortic valve implantation (TAVI). Methods: This is a retrospective study. A total of 35 patients underwent TAVI and received pacemaker implantation from January 2018 to December 2020 in Beijing Fuwai Hospital were enrolled. Patients were divided into LBBP group (n=12) and right ventricular apex pacing (RVAP) group (n=23) according to the pacing position. The success rate of operation in LBBP group was calculated, and the occurrence of complications were observed, and the parameters of pacemaker were measured on the 3rd day and 1, 3 and 6 months after operation. The N-terminal pro-B-type natriuretic peptide (NT-proBNP), echocardiographic and ECG indexes were compared between the two groups on the 3rd day and 1, 3, and 6 months after pacemaker implantation. Result: A total of 35 patients were included, The age was (76.4±7.7) years, including 19 males (54.3%). The procedure time ((86.58±17.10)min vs. (68.74±9.18)min, P<0.001) and fluoroscopy duration ((20.08±4.44)min vs. (17.00±2.26)min, P<0.001) were significantly longer in LBBP group compared with RVAP group. The operation success rate of LBBP group was 11/12. There was no serious operation related complications such as pneumothorax, hemothorax, electrode dislocation, infection, and lower limb bleeding. The patients were followed up for 7.43 (5.21, 9.84) months. The programmed parameters of pacemaker were in the ideal range and stable during follow-up. At 3 and 6 months after operation, the left ventricular ejection fraction in LBBP group was higher than that in RVAP Group (at 3 months: (60.75±2.89)% vs. (57.35±3.33)%, P=0.004; at 6 months: (63.17±3.33)% vs. (56.17±3.97)%, P<0.001), NT-proBNP values was lower in LBBP group than that in RVAP Group (at 3 months: 822 (607, 1 150)ng/L vs. 1 052 (902, 1 536)ng/L, P=0.006; at 6 months: 440 (330,679)ng/L vs. 783 (588, 1 023)ng/L, P=0.001). At 1, 3 and 6 months after operation, the QRS duration was shorter in LBBP group than that in RVAP group (1 month: 99 (97, 107)ms vs. 126(124, 130)ms, P<0.001; 3 months: 98(96, 105)ms vs. 129(128, 133)ms, P<0.001; 6 months: 96(94, 104)ms vs. 130(128, 132)ms, P<0.001). Conclusions: For patients with permanent pacemaker indications after TAVI, LBBP is feasible, safe and reliable. It could improve the cardiac function in the short term, the long-term effect of LBBP needs to be further observed.


Subject(s)
Aged , Aged, 80 and over , Humans , Male , Bundle of His , Cardiac Pacing, Artificial/methods , Electrocardiography/methods , Fluoroscopy , Retrospective Studies , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Function, Left
7.
Chinese Journal of Cardiology ; (12): 543-548, 2022.
Article in Chinese | WPRIM | ID: wpr-940886

ABSTRACT

Objective: To evaluate the success rate of His-Purkinje system pacing (HPSP) in patients with various sites of atrioventricular block (AVB) and provide clinical evidence for the selection of HPSP in patients with AVB. Methods: This is a retrospective case analysis. 637 patients with AVB who underwent permanent cardiac pacemaker implantation and requiring high proportion of ventricular pacing from March 2016 to September 2021 in the Department of Cardiology, General Hospital of Northern Theater Command were enrolled. The site of AVB was determined by electrophysiological examination. His bundle pacing (HBP) was performed in the first 130 patients (20.4%) who were classified as the HBP group and HPSP included HBP and/or left bundle branch pacing (LBBP) was performed in later 507 patients (79.6%) and these patients were classified as the HPSP group. The basic clinical information such as age and sex of the two groups was compared, and the success rates of HBP or HPSP in patients with different sites of AVB and QRS intervals were analyzed. Results: The age of HBP group was (66.4±15.9) years with 75 males (57.7%). The age of HPSP group was (66.8±13.6) years with 288 (56.8%) males. Among 637 patients, 63.0% (401/637) had atrioventricular node block; 22.9% (146/637) had intra-His block; 14.1% (90/637) had distal or inferior His bundle block. Totally, the success rate of HPSP was higher than that of HBP [93.9% (476/507) vs. 86.9% (113/130), P<0.05]. In each group of patients with various AVB sites, the success rate of HPSP was higher than that of HBP respectively and both success rates of HBP and HPSP showed a declining trend with the distant AVB site. The success rate of HBP in patients with atrioventricular node block and intra-His block was higher than that in patients with distal or inferior His bundle block [95.2% (79/83) vs. 47.1% (8/17), P<0.001; 86.7% (26/30) vs. 47.1% (8/17), P=0.010]. The success rate of HPSP was higher than that of HBP in patients with distal or inferior His bundle block [87.7% (64/73) vs 47.1% (8/17), P=0.001]. In patients with QRS<120 ms, 94.9% (520/548) of AVB sites were in atrioventricular node or intra-His, and HBP had a similar high success rate with HPSP [95.6% (109/114) vs. 96.3% (418/434), P=0.943] in these patients. In patients with QRS ≥ 120 ms, 69.7% (62/89) of AVB sites were at distal or inferior His bundle, and the success rate of HBP was only 25.0% (4/16), while the success rate of HPSP was as high as 79.5% (58/73), P<0.001. Conclusions: In patients with QRS<120 ms and atrioventricular node block or intra-His block, success rates of HBP and HPSP are similarly high and HBP might be considered as the first choice. In patients with QRS ≥ 120 ms and AVB site at distal or inferior His bundle, the success rate of HPSP is higher than that of HBP, suggesting LBBP should be considered as the first-line treatment option.


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Atrioventricular Block/therapy , Bundle of His/physiology , Cardiac Pacing, Artificial , Electrocardiography , Retrospective Studies , Treatment Outcome
8.
Arch. cardiol. Méx ; 91(1): 93-99, ene.-mar. 2021. graf
Article in Spanish | LILACS | ID: biblio-1152865

ABSTRACT

Resumen La terapia de resincronización cardiaca mediante estimulación hisiana ha demostrado ser efectiva en pacientes con bloqueo de rama izquierda del haz de His e insuficiencia cardiaca. Paciente masculino, con 47 años de edad, con insuficiencia cardiaca, fracción de expulsión del 17% y miocardio dilatada idiopática, electrocardiograma en ritmo sinusal, bloqueo auriculoventricular de 1.er grado, intervalo PR 400 ms, bloqueo completo de rama derecha del haz de His, bloqueo del fascículo anterior de la rama izquierda del haz de His, duración del QRS 200 ms. Se decidió realizar estimulación selectiva del haz de His. La resincronización cardiaca biventricular convencional en pacientes con presencia de bloqueo completo de la rama derecha del haz de His no está indicada debido a la pobre respuesta al tratamiento. La estimulación hisiana permite reclutar la rama bloqueada y reestablecer la conducción a través de ella, de tal forma que, en ausencia de necrosis, se logre sincronía biventricular. En el caso presentado el reclutamiento de la rama derecha mediante estimulación hisiana se reflejó en el restablecimiento de la sincronía biventricular, medida por rastreo de marcas (speckle tracking) e incremento significativo de la fracción de expulsión del ventrículo izquierdo del 17 al 36.6%, con un incremento absoluto del 19.6%.


Abstract Cardiac resynchronization therapy has proven to be an effective therapy in patients with left bundle branch block and heart failure. Male, 47 years old, heart failure with a left ventricle ejection fraction of 17%, idiopathic heart failure. ECG with sinus rhythm, 1st degree AV block, PR 400 ms, complete right bundle branch block, anterior hemi-fascicle of the left bundle of His, and QRS duration 200 ms. We decided to perform a selective His bundle pacing. In patients with right bundle branch block the biventricular cardiac resynchronization is not indicated due to low treatment response. His bundle pacing allows recruiting the blocked branch and restoring conduction throughout it, therefore, in the absence of necrosis the biventricular synchrony is achieved. We presented a case of His bundle pacing with recruitment of the right bundle branch, which reestablish biventricular synchrony measured by speckle tracking, and with a significant increase of the left ventricle ejection fraction from 17 to 36.6%, with an absolute increase of 19.6%.


Subject(s)
Humans , Male , Middle Aged , Bundle-Branch Block/therapy , Bundle of His , Cardiac Resynchronization Therapy , Bundle-Branch Block/complications , Heart Failure/complications
9.
Arq. bras. cardiol ; 116(1): 119-126, Jan. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1152966

ABSTRACT

Resumo Fundamento A ablação da taquicardia atrial (TA) com local de ativação mais precoce próxima ao feixe de His é um desafio, devido ao risco de bloqueio de AV completo por sua proximidade ao sistema de His-Purkinje (SHP). Uma alternativa para minimizar esse risco é posicionar o cateter na cúspide não coronária (CNC), que é anatomicamente contígua à região para-Hissiana. Objetivos O objetivo deste estudo foi fazer uma revisão de literatura e avaliar as características eletrofisiológicas, a segurança e o índice de sucesso de aplicação de radiofrequência (RF) por cateter na CNC para o tratamento de TA para-Hissiana em uma série de casos. Métodos Avaliamos retrospectivamente dez pacientes (Idade: 36±10 anos) que foram encaminhados para ablação de taquicardia paroxística supraventricular (TPSV) e haviam sido diagnosticados com TA focal para-Hissiana confirmada por manobras eletrofisiológicas clássicas. Para a análise estatística, um P valor d <0.05 foi considerado estatisticamente significativo. Resultados A ativação atrial mais precoce na posição His foi de 28±12ms da onda P, e a CNC foi 3±2ms antes da posição His, sem evidência de potencial His em todos os pacientes. Foi aplicada RF à CNC (cateter de ponta de 4-mm; 30W, 55°C) e a taquicardia foi interrompida em 5±3s sem aumento no intervalo PR ou evidência de um ritmo juncional. Os testes eletrofisiológicos não induziram novamente a taquicardia em 9/10 pacientes. Não houve complicações em nenhum procedimento. Durante o período de acompanhamento de 30 ± 12 meses, nenhum paciente apresentou recorrência de taquicardia. Conclusão O tratamento percutâneo de TA para-Hissiana por meio de CNC é uma estratégia segura e eficiente, tornando-se uma opção interessante para o tratamento de arritmia complexa. (Arq Bras Cardiol. 2021; 116(1):119-126)


Abstract Background Atrial tachycardia (AT) ablation with earliest activation site close to the His-Bundle is a challenge due to the risk of complete AV block by its proximity to His-Purkinje system (HPS). An alternative to minimize this risk is to position the catheter on the non-coronary cusp (NCC), which is anatomically contiguous to the para-Hisian region. Objectives The aim of this study was to perform a literature review and evaluate the electrophysiological characteristics, safety, and success rate of catheter-based radiofrequency (RF) delivery in the NCC for the treatment of para-Hisian AT in a case series. Methods This study performed a retrospective evaluation of ten patients (Age: 36±10 y-o) who had been referred for SVT ablation and presented a diagnosis of para-Hisian focal AT confirmed by classical electrophysiological maneuvers. For statistical analysis, a p-value of <0.05 was considered statistically significant. Results The earliest atrial activation at the His position was 28±12ms from the P wave and at the NCC was 3±2ms earlier than His position, without evidence of His potential in all patients. RF was applied on the NCC (4-mm-tip catheter; 30W, 55ºC), and the tachycardia was interrupted in 5±3s with no increase in the PR interval or evidence of junctional rhythm. Electrophysiological tests did not reinduce tachycardia in 9/10 of patients. There were no complications in all procedures. During the 30 ± 12 months follow-up, no patient presented tachycardia recurrence. Conclusion The percutaneous treatment of para-Hisian AT through the NCC is an effective and safe strategy, which represents an interesting option for the treatment of this complex arrhythmia. (Arq Bras Cardiol. 2021; 116(1):119-126)


Subject(s)
Humans , Adult , Tachycardia, Supraventricular/therapy , Catheter Ablation , Bundle of His/surgery , Retrospective Studies , Electrocardiography , Heart Atria/surgery , Middle Aged
11.
Journal of Central South University(Medical Sciences) ; (12): 379-384, 2021.
Article in English | WPRIM | ID: wpr-880670

ABSTRACT

OBJECTIVES@#To compare the left ventricular systolic function between the 1eft bundle branch pacing (LBBP) and right ventricular septum pacing (RVSP) in patients with pacemaker dependence by three-dimensional speckle tracking imaging (3D-STI).@*METHODS@#A total of 65 patients with atrioventricular block (AVB) (Mobitz type II second-degree AVB, high-degree AVB, or third-degree AVB), who underwent permanent cardiac pacing implantation including 32 patients receiving LBBP (LBBP group) and 33 patients receiving RVSP (RVSP group) from June 2018 to June 2019,were enrolled in this study. These patients met the following inclusion criterion: pre-operative left ventricular ejection fraction (LVEF)>50% and ventricular pacing rate>40% at 6-month programming follow-up; and the patients underwent echocardiography at pre-operation and 6 months after operation. The 3D-STI was used to obtain global longitudinal strain (GLS), global circumferential strain (GCS), global radial strain (GRS), and global area strain (GAS).@*RESULTS@#All the patients in the LBBP group and the RVSP group had normal LVEF, there was no significant difference between the 2 group (@*CONCLUSIONS@#For patients with pacemaker dependence and normal LVEF at pre-operation, the cardiac function in the LBBP group is not significantly better than that in the RVSP group in short term follow-up. But in terms of physiologic pacing and long-term cardiac function protection, the 1eft bundle branch pacing is an optimal pacing mode.


Subject(s)
Humans , Bundle of His , Cardiac Pacing, Artificial , Pacemaker, Artificial , Stroke Volume , Ventricular Function, Left , Ventricular Septum/diagnostic imaging
13.
Arq. bras. cardiol ; 114(2): 284-292, Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088875

ABSTRACT

Abstract Background: Diastolic dysfunction, commonly evaluated by echocardiography, is an important early finding in many cardiomyopathies. Cardiac magnetic resonance (CMR) often requires specialized sequences that extends the test time. Recently, feature-tracking imaging has been made available, but still requires expensive software and lacks clinical validation. Objective: To assess diastolic function in patients with aortic valve disease (AVD) and compare it with normal controls by evaluating left ventricular (LV) longitudinal displacement by CMR. Methods: We compared 26 AVD patients with 19 normal controls. Diastolic function was evaluated as LV longitudinal displacement in 4-chamber view cine-CMR images using steady state free precession (SSFP) sequence during the entire cardiac cycle with temporal resolution < 50 ms. The resulting plot of atrioventricular junction (AVJ) position versus time generated variables of AVJ motion. Significance level of p < 0.05 was used. Results: Maximum longitudinal displacement (0.12 vs. 0.17 cm), maximum velocity during early diastole (MVED, 0.6 vs. 1.4s-1), slope of the best-fit line of displacement in diastasis (VDS, 0.22 vs. 0.03s-1), and VDS/MVED ratio (0.35 vs. 0.02) were significantly reduced in AVD patients compared with controls, respectively. Aortic regurgitation showed significantly worse longitudinal LV shortening compared with aortic stenosis. Higher LV mass indicated worse diastolic dysfunction. Conclusions: A simple linear measurement detected significant differences on LV diastolic function between AVD patients and controls. LV mass was the only independent predictor of diastolic dysfunction in these patients. This method can help in the evaluation of diastolic dysfunction, improving cardiomyopathy detection by CMR, without prolonging exam time or depending on expensive software.


Resumo Fundamentos: A disfunção diastólica, comumente avaliada por ecocardiografia, é um importante achado precoce na maioria das cardiomiopatias. A ressonância magnética cardíaca (RMC) frequentemente requer sequências específicas que prolongam o tempo de exame. Recentemente, métodos de imagens com monitoramento de dados (feature-tracking) foram desenvolvidos, mas ainda requerem softwares caros e carecem de validação clínica. Objetivos: Avaliar a função diastólica em pacientes com doença valvar aórtica (DVA) e compará-la a controles normais pela medida do deslocamento longitudinal do ventrículo esquerdo (VE) por RMC. Métodos: Nós comparamos 26 pacientes com DVA com 19 controles normais. A função diastólica foi avaliada como uma medida do deslocamento longitudinal do VE nas imagens de cine-RMC no plano quatro câmaras usando a sequência steady state free precession (SSFP) durante todo o ciclo cardíaco com resolução temporal < 50 ms. O gráfico resultante da posição da junção atrioventricular versus tempo gerou variáveis de movimento da junção atrioventricular. Utilizamos nível de significância de p < 0,005. Resultados: Deslocamento longitudinal máximo (0,12 vs. 0,17 cm), velocidade máxima em início de diástole (0,6 vs. 1,4s-1), velocidade máxima na diástase (0,22 vs. 0,03s-1) e a razão entre a velocidade máxima na diástase e a velocidade máxima em diástole inicial (0,35 vs. 0,02) foram significativamente menores nos pacientes com DVA em comparação aos controles normais, respectivamente. Pacientes com insuficiência aórtica apresentaram medidas de encurtamento longitudinal do VE significativamente piores em comparação aqueles com estenose aórtica. O aumento da massa ventricular esquerda indicou pior disfunção diastólica. Conclusões: Esta simples medida linear detectou diferenças significativas na função diastólica do VE entre pacientes com DVA e controles normais. A massa ventricular esquerda foi o único preditor independente de disfunção diastólica nesses pacientes. Este método pode auxiliar na avaliação da disfunção diastólica, melhorando a detecção de cardiomiopatias por RMC sem prolongar o tempo de exame ou depender de caros softwares.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aortic Valve Insufficiency/physiopathology , Aortic Valve Stenosis/physiopathology , Ventricular Dysfunction, Left/physiopathology , Diastole/physiology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Reference Values , Atrioventricular Node/physiopathology , Atrioventricular Node/diagnostic imaging , Time Factors , Bundle of His/physiopathology , Bundle of His/diagnostic imaging , Case-Control Studies , Linear Models , Retrospective Studies , Ventricular Function, Left/physiology , Ventricular Dysfunction, Left/diagnostic imaging , Statistics, Nonparametric , Magnetic Resonance Imaging, Cine/methods
15.
Enferm. foco (Brasília) ; 10(4): 93-100, 2019. tab
Article in Portuguese | LILACS, BDENF | ID: biblio-1052805

ABSTRACT

Objetivo: verificar o impacto dos bundles e o aprendizado interprofissional na prevenção de pneumonia associada à ventilação mecânica de uma unidade de terapia intensiva (UTI). Método: estudo quasi-experimental realizado em uma UTI de um hospital público de Diamantina, Minas Gerais. Foram incluídos neste estudo 56 profissionais que prestavam assistência direta a pacientes em ventilação mecânica. A coleta de dados ocorreu em três fases: pré-intervenção, que consistiu em observação direta e entrevista; intervenção, na qual o treinamento foi realizado por meio de simulações clínicas; e pós-intervenção, na qual foi avaliado o impacto das estratégias implementadas por observação direta. As diferenças entre os grupos pré- e pós-intervenção foram avaliadas pelo teste de McNemar. Foi utilizado um nível alfa de 0,05 definido a priori, e a correção de Bonferroni determinou significância estatística para o caso de comparações múltiplas. Resultados: após a intervenção, houve aumento da adesão à pressão endotraqueal do cuff (8,10%), interrupção diária da sedação (16,67%), e aspiração subglótica (18,75%). As associações entre categoria profissional versus ausência de aspiração, posicionamento da cabeceira da cama, frequência de higiene bucal, e tipo de higiene das mãos após a intervenção foram significativas (p < 0,0083). Conclusões: ainda existe uma lacuna a ser detectada na implementação do bundle e o impacto positivo gerado pelo conhecimento interprofissional, principalmente porque não é imediato, mas a longo prazo, para obter o feedback desejado. (AU)


Objective: to verify the impact of the bundles and the interprofessional learning for the prevention of mechanical ventilation-associated pneumonia of an intensive care unit (ICU). Method: This was a quasi-experimental study performed in an ICU of a public hospital in Diamantina, Minas Gerais. Were included in this study 56 professionals who provided direct assistance to patients in mechanical ventilation. The data collection took place in three phases: pre-intervention, which consisted of direct observation and interview; intervention, in which training was performed through clinical simulations; and post-intervention, in which the impact of the strategies implemented through direct observation, was evaluated. Differences between pre and post groups were assessed using McNemar's test. An alpha level of 0.05 set a priori was used, and a Bonferroni correction determined statistical significance for the case of multiple comparisons. Results: After the intervention, there was increased adherence to endotracheal cuff pressure (8.10%), daily interruption of sedation (16.67%) and subglottic aspiration (18.75%). It was significant (p < 0,0083) in the associations between the professional category versus non-aspiration, bed head positioning, oral hygiene frequency and the type of hand hygiene after intervention. Conclusions: There is still a gap to be detected in the bundle implementation and the positive impact generated by the inter-professional knowledge, mainly because it is not immediate but in the long term to obtain the desired feedback. (AU)


Objetivo: verificar el impacto de los bundles y el aprendizaje interprofesional para la prevención de la neumonía asociada a la ventilación mecánica de una unidad de cuidados intensivos (UCI). Método: Este fue un estudio cuasi experimental realizado en una UCI de un hospital público en Diamantina, Minas Gerais. Se incluyeron en este estudio 56 profesionales que prestaron asistencia directa a los pacientes en ventilación mecánica. La recolección de datos se realizó en tres fases: pre-intervención, que consistió en observación directa y entrevista; intervención, en la cual se realizó entrenamiento por medio de simulaciones clínicas; y post-intervención, en que se evaluó el impacto de las estrategias de observación directa. Las diferencias entre los grupos pre y post se evaluaron mediante la prueba de McNemar. Se usó un nivel alfa de 0,05 a priori, y se usó una corrección de Bonferroni para determinar la significación estadística en el caso de comparaciones múltiples. Resultados: Después de la intervención, hubo aumento de la adhesión al monitoreo de la presión del cuff endotraqueal (8,10%), interrupción diaria de la sedación (16,67%) y aspiración subglótica (18,75%). Fue significativa (p < 0,0083) las asociaciones entre la categoría profesional frente a la no aspiración, la posición de la cabecera de la cama, la frecuencia de higiene oral y el tipo de higiene de las manos después de la intervención. Conclusiones: Aún existe una laguna a ser detectada en la implantación del bundle y el impacto positivo generado por el conocimiento interprofesional, principalmente por no ser inmediato, pero a largo plazo, para obtener el feedback deseado. (AU)


Subject(s)
Pneumonia, Ventilator-Associated , Bundle of His , Infection Control , Total Quality Management , Public Health Surveillance , Intensive Care Units
16.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 31(3)jul.-set. 2018. ilus
Article in Portuguese | LILACS | ID: biblio-967708

ABSTRACT

A estimulação artificial do feixe de His garante uma despolarização harmônica e sincronizada de ambos os ventrículos e já vem sendo estudada há mais de 50 anos. O aproveitamento e o desenvolvimento de ferramentas e cabos-eletrodos colaboraram para impulsionar o implante de marcapassos com estimulação hissiana de maneira rotineira em humanos, principalmente nos últimos 15 anos. Segundo as evidências atuais, essa modalidade de estimulação é promissora como alternativa à estimulação ventricular direita monossítica tradicional pela redução potencial dos prejuízos induzidos pela estimulação artificial, tais como queda da fração de ejeção, internações hospitalares por insuficiência cardíaca e até morte. O uso do marcapasso com estimulação hissiana também já foi descrito como alternativa para pacientes com indicação de terapia de ressincronização cardíaca, com resultados animadores. O limiar de comando mais elevado, as potenciais inibições ou perdas de captura ventricular por oversensing (far-field atrial), e os possíveis deslocamentos do cabo-eletrodo pela movimentação do folheto septal da valva mitral são problemas a serem considerados antes do implante de marcapasso com estimulação hissiana. Ensaios clínicos com grande número de participantes e alto poder estatístico ainda são necessários para a melhor compreensão dos benefícios da estimulação hissiana a médio e longo prazos, comparativamente à estimulação tradicional do ventrículo direito e às terapias de ressincronização cardíaca


His-bundle pacing provides a harmonic and synchronized depolarization of both ventricles. It has been studied for more than 50 years. The development of new tools and leads has helped improve the implantation of pacemakers with His-bundle pacing routinely, especially in the last 15 years. According to current evidences, this modality of pacing is a promising alternative to traditional single-site right ventricular pacing for a potential reduction of artificial pacing-induced damages, such as ejection fraction decrease, hospital admission due to heart failure and even death. The use of His-bundle pacing has also been described as an alternative to cardiac resynchronization therapy with encouraging results. Higher command threshold, inappropriate inhibitions or oversensing ventricular loss of capture (atrial far-field) and potential lead displacements by septal leaflet motion of the mitral valve must be considered before implantation of a His-bundle pacemaker. Large randomized clinical trials with high statistical power are still needed for a better understanding of the benefits of His-bundle pacing at medium and long-term in comparison to traditional right ventricle pacing and cardiac resynchronization therapies


Subject(s)
Humans , Male , Female , Cardiac Resynchronization Therapy/methods , Cardiac Resynchronization Therapy Devices , Pacemaker, Artificial , Stroke Volume , Tricuspid Valve , Bundle of His , Electric Stimulation , Electrocardiography/methods , Electrodes , Electrophysiology/methods , Heart Ventricles , Mitral Valve
18.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 31(1): 8-12, jan.-mar. 2018. ilus
Article in Portuguese | LILACS | ID: biblio-905668

ABSTRACT

diagnóstico concomitante de bloqueio de ramo esquerdo e bloqueio divisional ântero-superior esquerdo é motivo de controvérsias entre cardiologistas, principalmente quando há desvio do eixo vetorcardiográfico do coração para a esquerda. Em uma breve revisão da literatura, descrevemos a anatomia do feixe de His e sua natureza trifascicular, apresentamos a teoria tetrafascicular de Medrano e relembramos os critérios diagnósticos dessas duas entidades eletrocardiográficas. Concluímos que o bloqueio concomitante pode ser encontrado em casos de bloqueios pós-divisionais bifasciculares com maior acometimento do bloqueio divisional ântero-superior. Por outro lado, o cardiologista precisa ter em mente que existem outras causas de desvio do eixo para a esquerda em vigência de bloqueio de ramo esquerdo, entre elas: bloqueio de ramo esquerdo com infarto inferior, bloqueio de ramo esquerdo com infarto agudo do miocárdio ântero-septal e lateral, e vias acessórias atípicas


The concomitant diagnosis of left bundle branch block and anterosuperior hemi-block is controversial among cardiologists, especially when there is left vectorcardiographic axis deviation. In a brief literature review, we describe His bundle's anatomy and its trifascicular nature, we present Medrano's quadrifascicular theory and revise the diagnostic criteria of these two electrocardiographic entities. We conclude that concomitant block might be found in cases of post-divisional bifascicular blocks with greater involvement of the anterosuperior hemiblock. On the other hand, the cardiologist must keep in mind that there are other causes of left axis deviation in the presence of left bundle branch block, such as: inferior infarction, anterior-septal and lateral infarction, and atypical bypass tracts


Subject(s)
Humans , Bundle-Branch Block , Electrocardiography/methods , Vectorcardiography/methods , Atrioventricular Node , Bundle of His/anatomy & histology , Heart , Heart Ventricles , Ventricular Septum
20.
Korean Circulation Journal ; : 1081-1096, 2018.
Article in English | WPRIM | ID: wpr-738673

ABSTRACT

We reviewed the anatomical characteristics of the conduction system in the ventricles of human and ungulate hearts and then raised some questions to be answered by clinical and anatomical studies in the future. The ventricular conduction system is a 3-dimensional structure as compared to the 2-dimensional character of the atrial conduction system. The proximal part consisting of the atrioventricular node, the bundle of His and fascicles are groups of conducting cells surrounded by fibrous connective tissue so as to insulate from the underlying myocardium. Their location and morphological characters are well established. The bundle of His is a cord like structure but the left and right fascicles are broad at the proximal and branching at the distal part. The more distal part of fascicles and Purkinje system are linear networks of conducting cells at the immediate subendocardium but the intra-mural network is detected at the inner half of the ventricular wall. The papillary muscle also harbors Purkinje system not in the deeper part. It is hard to recognize histologically in human hearts but conducting cells as well as Purkinje cells are easily recognized in ungulate hearts. Further observation on human and ungulate hearts with myocardial infarct, we could find preserved Purkinje system at the subendocardium in contrast to the damaged system at the deeper myocardium. Further studies are necessary on the anatomical characteristics of this peripheral conduction system so as to correlate the clinical data on hearts with ventricular arrhythmias.


Subject(s)
Humans , Arrhythmias, Cardiac , Atrioventricular Node , Bundle of His , Connective Tissue , Heart , Heart Conduction System , Myocardial Infarction , Myocardium , Papillary Muscles , Purkinje Cells , Purkinje Fibers , Tachycardia, Ventricular